Browse / CVEs / CVE-2025-41393
CVE-2025-41393· CWE-79
Ricoh Web Image Monitor - Reflected XSS
mediumseverity
6.1CVSS score
0.7%likelihood of exploitation, next 30 days
53%of all CVEs are less likely
Readycheck to confirm it
A reflected cross-site scripting vulnerability exists in the laser printers and MFPs (multifunction printers) which implement Ricoh Web Image Monitor. If exploited, an arbitrary script may be executed on the web browser of the user who accessed Web Image Monitor.
Impact
Attackers can execute malicious JavaScript in user browsers through the profile parameter, potentially leading to session hijacking and credential theft.
Fix
Apply the security patch from Ricoh for affected Web Image Monitor implementations.
How to confirm it
Send: GET {{BaseURL}}/?profile=</script><script>alert(document.domain)</script>
Positive when: contains "<script>alert(document.domain)</script>" and "websys/webArch/mainFrame.cgi" and "Web Image Monitor" AND status 200Run it with nuclei: nuclei -id CVE-2025-41393 -u <target>
The full check
id: CVE-2025-41393
info:
name: Ricoh Web Image Monitor - Reflected XSS
author: jpg0mez
severity: medium
description: |
A reflected cross-site scripting vulnerability exists in the laser printers and MFPs (multifunction printers) which implement Ricoh Web Image Monitor. If exploited, an arbitrary script may be executed on the web browser of the user who accessed Web Image Monitor.
impact: |
Attackers can execute malicious JavaScript in user browsers through the profile parameter, potentially leading to session hijacking and credential theft.
remediation: |
Apply the security patch from Ricoh for affected Web Image Monitor implementations.
reference:
- https://www.ricoh.com/products/security/vulnerabilities/vul?id=ricoh-2025-000001
- https://jvn.jp/en/jp/JVN20474768/
- https://nvd.nist.gov/vuln/detail/CVE-2025-41393
classification:
epss-score: 0.00679
epss-percentile: 0.5268
cvss-metrics: CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
cvss-score: 6.1
cwe-id: CWE-79
metadata:
verified: true
max-request: 1
shodan-query: http.html:"Web Image Monitor"
tags: cve,cve2025,ricoh,xss,web,intrusive,vuln
http:
- method: GET
path:
- "{{BaseURL}}/?profile=</script><script>alert(document.domain)</script>"
matchers-condition: and
matchers:
- type: word
part: body
words:
- '<script>alert(document.domain)</script>'
- 'websys/webArch/mainFrame.cgi'
- 'Web Image Monitor'
condition: and
- type: status
status:
- 200References
- https://www.ricoh.com/products/security/vulnerabilities/vul?id=ricoh-2025-000001
- https://jvn.jp/en/jp/JVN20474768/
- https://nvd.nist.gov/vuln/detail/CVE-2025-41393
Use this check only on systems you are authorised to test. Where the data comes from